Technical Bulletin
Software Enhancement to Improve Redundancy Fault Detection
Advisory
Date
September 1, 2003
Reference
133
Route to
Modernization Manager/Service Manager
From
MCE Technical Support Department
Equipment
All controllers designed for ASME A17.2000 (B44) with MP software
versions prior to 8.01.00, or with PCA versions prior to
6.0.0002.
Description
Over the past year, our experience with field installations of
ASME A17.2000 (B44) control systems has led us to design and
implement several product enhancements to our controller
software.
If you are experiencing redundancy faults without an apparent
cause, these faults could be caused by hardware timing issues. We
have designed a more sophisticated software redundancy fault
detection method to make the system more robust.
Action
If you are experiencing any of the symptoms described above, or
if you are unsure whether a problem you are experiencing may be
related to this issue, call MCE Technical Support to troubleshoot
the problem. If necessary, MCE will send new software and/or
hardware to correct the problem.
Help
Should you require additional technical assistance:
- Telephone 916/463-9200
- Touch "6" for Technical Support
- Refer to the reference number
above
|